≋PRIMSTEdgeCool

THERMAL INFRASTRUCTURE / ALWAYS EVOLVING

Always On.
Always Cool.

Cooling architecture for the next wave of compute.

Explore air, liquid and hybrid approaches for data centers, AI infrastructure and the intelligent edge.

DESIGNED AROUND YOUR COMPUTEExplore the system ↓
01 / AIR COOLING02 / LIQUID COOLING03 / HEAT REJECTION

01 / SOLUTIONS

A connected view
of cooling.

Start with the heat load. Build an architecture around your facility, climate and deployment strategy.

Discuss this architecture ↗

Concept architecture based on source slides 3, 5 and 14. Final selection requires project engineering.

02 / PRODUCT EXPLORER

Every layer.
One cooling strategy.

Explore reference product families, then open the detailed specifications to compare source models.

Supporting architecture: air- or water-cooled magnetic-bearing chillers, pumps, manifolds, secondary loop networks and UQD connectors appear in slides 3–4. Detailed selection data is not provided.

03 / TECHNOLOGY

Respond to the load.
Work with the climate.

Reference engineering concepts to evaluate for your project. Feature availability and performance require PRIMST confirmation.

DUAL-SOURCE OPERATING LOGIC

Free cooling

When outdoor conditions permit, the water coil uses the available natural cooling source.

Illustrative modes, not a live controller. No universal changeover temperature is assumed.

Airflow & containment

Separate hot and cold aisles to limit recirculation. Reference fan walls combine EC fans, coils, filters and water valves. Slim walls align with racks; remote walls serve a wider room layout. [Slides 8–9, 15–16]

Controls & integration

The source describes PID control, RS485, BMS or pLAN interfaces and optional temperature- or pressure-based fan control. Source claims of ±1°C control and optional 5% THDi are unverified for PRIMST. [Slide 16]

Liquid loop management

Reference CDU functions include differential pressure or flow control, dew-point tracking, bypass filtration and serviceable sensors. Some functions are optional. Source values: ±1°C secondary temperature control and ±0.1 bar pressure control. Cabinet networking supports up to six units in the source. [Slides 24–25]

Climate-aware heat rejection

Dry coolers may use dry operation, wetted-media precooling or spray assistance. Water availability, water quality and local ambient conditions govern selection. No PUE, WUE or energy saving is guaranteed here. [Slides 19–22]

04 / APPLICATIONS

Where compute goes,
cooling follows.

01 / HIGH-DENSITY COMPUTE

AI & large data centers

Evaluate cabinet CDUs for liquid loads, with fan walls for residual air cooling and a shared primary cooling source.

Plan a deployment ↗
02 / DISTRIBUTED COMPUTE

Edge & single-rack systems

Explore rack-integrated CDUs and room-level precision cooling where deployment space and service access matter.

Explore the edge ↗
03 / MODULAR INFRASTRUCTURE

Modular data halls

Consider slim walls alongside racks, aisle containment and cooling capacity that follows the planned rollout.

Discuss your layout ↗
04 / CRITICAL EQUIPMENT

Telecom & equipment rooms

Assess chilled-water precision cooling for communications rooms, equipment spaces and power battery rooms.

Define requirements ↗

Application guidance derived from slides 5, 9, 13 and 23–25. These are use cases, not PRIMST customer installations.

05 / START A CONVERSATION

Your next project.
Let's define it.

Tell us about your compute environment and cooling requirements.

Preview mode: this form prepares a downloadable project brief on your device. Nothing is sent or stored by PRIMST. An official contact channel must be configured before launch.

REFERENCE SPECIFICATIONS