# Source and verification register

Source: TICA data center thermal management presentation, August 2026 V2.2, 26 slides. All source capabilities and figures are reference material, not verified PRIMST specifications. No affiliation, resale authorization, product availability or certification is implied.

## Slide-by-slide disposition

| Slide | Source subject | Website treatment |
|---|---|---|
| 1 | Laboratories, accreditations and test facilities | Excluded from PRIMST claims |
| 2 | TICA customers | Excluded; no customer logos or implied endorsements |
| 3 | Common primary source for air and liquid cooling | Solutions conceptual architecture |
| 4 | Product family map and market ranking | Eight reference families; chillers, pumps, manifold, secondary loop and UQD noted; ranking excluded |
| 5 | Dual-source cooling architecture and applications | Hybrid architecture and application guidance |
| 6 | Parallel and series circuits; free, hybrid and mechanical modes | Technology mode selector. Parallel source circuit has three modes; series diagram shows free and hybrid modes. Selector is conceptual, not a complete piping diagram |
| 7 | Flexibility, distributed units and performance chart | Architecture concepts retained; efficiency and annual-hour claims excluded. The chart's 45 kW test and temperature labeling require independent verification |
| 8 | Remote dual-source wall construction and airflow | Product description; service sections and containment discussion |
| 9 | Near-rack slim wall and layouts | Product description and modular applications |
| 10 | Remote dual-source wall table | All cells transcribed and translated in data.js |
| 11 | Near-rack wall table | All cells retained, including TFW0090AD source model spelling and top pipe-box height notes |
| 12 | Dual-source precision AC table | All cells transcribed and translated |
| 13 | Chilled-water terminals and applications | Family ranges, upflow/downflow, telecom/equipment/battery room use cases |
| 14 | Water-cooled and air-cooled primary systems | Air solution explanation |
| 15 | Chilled-water wall airflow/control concepts | Technology discussion |
| 16 | Fans, maintenance and controls | RS485/BMS/pLAN and optional control features; ±1°C and optional 5% THDi explicitly unverified; component reliability guarantees excluded |
| 17 | Chilled-water wall table | All cells retained, including unusual large dimensions; no silent correction |
| 18 | Chilled-water precision AC table | All cells retained, including source connection and pipe-size differences |
| 19 | Dry cooler V-coil, EC fans and front maintenance | Reference family; no noise or savings promises |
| 20 | Dry / wetted-media / spray modes | Climate-aware heat rejection explanation |
| 21 | Climate/configuration combinations | Dry, wetted-media and spray options; below-wet-bulb, 3–8°C reduction, AI, PUE and WUE claims excluded pending verification |
| 22 | Three dry-cooler tables and rating conditions | All 24 model columns retained with separate configuration titles and rating conditions |
| 23 | Cabinet/rack CDU comparison | Family ranges and installation scale |
| 24 | Rack CDU 80 specifications and features | Full table; optional features and temperature-order caveat |
| 25 | Cabinet CDU applications and controls | Application and control discussion; optional features; group control up to six source units |
| 26 | Cabinet CDU 450/800/1350/2500 tables | Full table; temperature-order and range caveats |

## Reference ranges versus tabulated examples

Family ranges on slide 4 are broader than some detailed tables. Do not substitute one for the other:
- Remote dual-source wall: family 140–260 kW; listed models 150/200/220/250 kW.
- Near-rack wall: 45–90 kW; models 45/45/60/90 kW.
- Dual-source precision AC: family 20–120 kW; models 30/55/90 kW.
- Chilled-water wall: family 100–600 kW; models 155/210/350/500 kW.
- Chilled-water precision AC: family 20–230 kW; models 35/50/90/135/190/230 kW.
- Dry cooler: family 300–1,700 kW; detailed configurations span 340–1,418 kW overall.
- Rack CDU: family 20–100 kW; detailed example 80 kW.
- Cabinet CDU: family 300–2,500 kW; examples 450/800/1350/2500 kW. Slide 25 application wording instead describes 300–1,600 kW.

## Technical review required

CDU secondary temperature pairs appear reversed relative to conventional supply/return terminology. Preserve source labels and values until engineering confirms direction. Dry cooler ratings use 50% ethylene glycol and stated ambient/fluid temperatures; capacities are not universal. Supply voltage/frequency varies by source model and does not establish regional compliance. The source provides no verified PRIMST SKUs, contact details, certifications, warranties or measured performance.

## Editorial policy

Original CSS illustrations are conceptual, not product representations. Source product images and source logos are not reused. Data is editable in data.js; translated full tables retain original model codes for traceability. Before commercial launch, obtain PRIMST approval of product mapping, every specification, optional feature, region, contact destination and legal copy. Do not remove caveats solely by changing the `verified` field: visible copy must be reviewed too.